===HEAT BALANCE===
BOILER
OUTLET TEMPERATURE(F): 830 OUTLET pressure(psia): 950
STEAM FLOW(#/hr) : 373000 BLOWDOWN FLOW(frac) : .02
BLR/TURB DELTA P(psia) : 50 HHV EFFICIENCY(frac) : .75
TURBINE
TURBINE EFF(frac) : .849 ALT/GEARBOX EFF(frac) : .973
CONDENSER
PRESSURE(in HgA) : 2 NET MAKEUP FLOW(frac) : .015
DEA/FW HEATERS (Enter Pressure=0 where absent) (RHT=reheat point)
#1 PRESSURE(psia) : 207.7 #1 GLAND STM EXH(frac) : 0
(RHT) #2 PRESSURE(psia) : 100 #2 GLAND STM EXH(frac) : 0
(DEA) #3 PRESSURE(psia) : 35 #3 GLAND STM EXH(frac) : .01187
#4 PRESSURE(psia) : 8 #4 GLAND STM EXH(frac) : .0035
Reheat(0=no, 1=yes) : 0 If optimize FWH's list max allowable boiler
inlet TEMP(F) (0=no limit) : 380